Thiết bi đo trở kháng vòng lặp Sonel MZC-305

Có: 0 sản phẩm trong giỏ

Thiết bi đo trở kháng vòng lặp Sonel MZC-305
  • Mã SP:
  • Giá NY: Liên hệ
  • Giá bán: Liên hệ
  • Tình trạng:
  • Khuyến mãi:
  • Lượt xem: 3261
  • Tags: Bàn Map
Đơn vị tiền tệ
  • Số lượng:
  • Thành tiền

- Hãng sản xuất: Sonel

- Model: MZC-305

- Xuất xứ: Ba Lan

  • Loop impedance measurement with resolution 0,01
  • Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01 (100...440V)
  • Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
  • Short circuit current indication
  • Voltage measurement up to 750V and up to 250V with resolution 0,1V
  • Measurements using Uni-Schuko adapter or test wires 1,2; 5; 10 and 20m
  • Memory of 990 records
  • USB connection with PC
  • Powered by disposable or rechargeable (4xAA)

Measurement of short circuit loop impedance (ZL-PE, ZL-N, ZL-L)

Measuring range according to IEC61557: 0,13…1999? for 1,2m test leads; 0,25…1999? for UNI-SCHUKO adapter

Range

Resolution

Accuracy

0,00...19,99Ω

0,01Ω

±(5% m.v. + 3 digits)

20,0...199,9Ω

0,1Ω

±(4% m.v.. + 3 digits)

200...1999Ω

• rated operating voltage UnL-N/ UnL-L: 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V, 400/690V,
• operating voltage range: 100…440V (for ZL-PE and ZL-N) and 100…750V (for ZL-L)
• high current measurement (up to 30A),
• operating frequency range: 45…65Hz,
• control of correctness of PE terminal connection by means of a contact electrode (applicable to ZL-PE),
• measurement is also possible when L and N circuits are swapped,
• measurement of resistance and reactance components,
• short circuit current calculation.

Measurement of short circuit loop impedance ZL-PE RCD (without RCD tripping)

Measuring range according to IEC61557: 0,43...1999? for 1,2m test leads; 0,50...1999? for UNI-SCHUKO adapter

Range

Resolution

Accuracy

0,00...19,99Ω

0,01Ω

±(6% m.v. + 10 digits)

20,0...199,9Ω

0,1Ω

±(6% m.v. + 5 digits)

200...1999Ω

• operating voltage range: 100 ... 440V,
• rated operating voltage Un: 110V, 115V, 127V, 220V, 230V, 240V, 390V, 400V,
• control of correctness of PE terminal connection by means of a contact electrode,
• measurement is also possible when L and N circuits are swapped,
• measurement of resistance and reactance components,
• short circuit current calculation.

Voltage measurement

 

Range

Resolution

Accuracy

0,0V...249,9V

0,1V

±(2% m.v. + 4 digits)

250V...750V

1V

±(2% m.v. + 2 digits)

• measurement available for all settings of short-circuit loop (ZL-PE, ZL-PE RCD and ZL-N,L-L),
• frequency range 45…65Hz,
• overvoltage alarm.

Electrical safety:
- type of insulation: double, according to IEC 61010-1
- measurement category: CAT IV 600V (CAT III 1000V)
- protection class acc. to EN 60529: IP54

Other technical data

- power supply: alkaline batteries or NiMH rechargeable batteries, size AA (4 pcs)
- number of Z measurements (for alkaline batteries): >3000 (2 measurements per minute)
- time to Auto-OFF: 120 seconds
- data transmission: USB
- memory of measurement results: 990 cells, 3500 entries
- display: LCD segment
- dimensions: 260x190x60mm
- meter weight: ca. 2,2 kg

Rated operational conditions:
- operating temperature: 0...+45°C
- storage temperature: -20...60°C
- humidity 20-80%

The instrument meets the requirements of EMC standards

 

Link Exchange: Duong Ren - Kinh Hien Vi - Panme - Ban Map - Thuoc Cap-